<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-07 17-09-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 73 dBuV P3 SR
Pilot RDS Phase Difference
6.5 kHz 3.1 kHz 77 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 27 kHz 11960 0,4682
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,9 dBr -0,95 dBr 1,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 9 (Varied) 0 1 1 9 16:09, 7.07.2025
RT
"Lf System - Afraid To Feel ta Björck och Siri Fagerudd "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E201, E402, E424
FM Scope Max at: 27 kHz MIN: 9 kHz % above 76 kHz: 0,4682 Acquired: 2025/07/07 17.08.19 Total samples: 11960 Equivalent time: 0:09:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 1,2 dBr MIN: -1,9 dBr AVE: -0,95 dBr % above 12,2 dBr: 0,0 Last value: 0,3 dBr (2025/07/07 17.08.18) 16.54 16.56 16.58 17.00 17.02 17.04 17.06 17.08 -2 -1 0 1 2 Pm [dBr]